Home / bedleveling / cartographer
Cartographer Probe¶
The Cartographer Probe is a sophisticated bed-leveling sensor that uses frequency-based detection to provide highly accurate and reliable bed leveling. It's particularly well-suited for Voron printers and other high-performance 3D printers.
Features¶
- Advanced Technology:
- Frequency-based detection
- Temperature independence
- High precision
- Multi-material support
- Smart Features:
- Automatic calibration
- Real-time monitoring
- LED status indicators
- Configurable sensitivity
- Reliability:
- Consistent measurements
- Long service life
- Minimal maintenance
- Robust design
Benefits¶
- Superior Accuracy:
- Frequency-based detection
- Temperature stability
- Consistent measurements
- Reliable first layers
- Time Efficiency:
- Quick setup process
- Automatic calibration
- Reduced manual adjustments
- Versatility:
- Works with various bed materials
- Compatible with multiple printer types
- Supports different mounting configurations
User Experiences¶
From Voron Discord User
"The Cartographer's frequency-based detection is incredibly reliable. I've been using it for over a year now, and it's never let me down. The temperature independence is a huge plus for enclosed printers."
From Reddit User Review
"The Cartographer is accurate when it works, but the initial tuning is a nightmare. I spent days trying to get it calibrated properly. The sensitivity to electrical noise is also a real issue - I had to reroute all my cables to get stable readings."
Community Feedback
- Users appreciate the temperature independence
- Many report excellent long-term reliability
- The frequency-based detection is praised for its accuracy
- Great for users who want a set-and-forget solution
- Active development and community support
Common User Complaints
- Initial tuning is extremely challenging and time-consuming
- Very sensitive to electrical noise and interference
- Requires careful cable routing and shielding
- Mounting and alignment are critical and unforgiving
- May need recalibration after major printer changes
- Documentation is technical and assumes prior knowledge
- Support is primarily community-based
- Some users report inconsistent behavior with certain bed materials
- Firmware updates can require complete recalibration
- Price is high compared to simpler alternatives
Installation Guide¶
Hardware Setup¶
- Mounting:
- Mount the probe 2-3mm above the nozzle
- Ensure proper alignment with the bed
-
Secure all connections firmly
-
Wiring:
- Connect signal wire to the probe
- Route cables away from stepper motors
- Secure cables to prevent interference
Software Configuration¶
-
Klipper Setup:
-
Calibration:
- Run initial calibration
- Set Z-offset
- Configure mesh leveling
Usage Tips¶
Best Practices
- Perform calibration at operating temperature
- Clean the bed surface before leveling
- Check probe alignment regularly
- Update firmware when available
Common Issues
- Incorrect mounting height
- Loose connections
- Interference from other electronics
- Outdated firmware
Advanced Configuration¶
Frequency Tuning¶
Multi-Material Support¶
Troubleshooting¶
Common Problems¶
- Inconsistent Readings:
- Check mounting height
- Verify connections
-
Clean probe surface
-
Calibration Issues:
- Ensure proper temperature
- Check bed surface
-
Verify probe alignment
-
Communication Errors:
- Check signal connection
- Verify firmware version
- Restart Klipper